SM重口

Ongoing changes to fire safety legislation in multi-occupied residential premises including high rise


Fire Safety Information for Responsible Persons including Freeholders, Managing Agents, and Right to Manage Companies

2022 and 2023 saw changes to fire safety legislation in residential buildings. Whilst certainly needed to ensure the continued safety of residents, LFRS fully understands that regulatory change can cause uncertainty and this page will be updated in line with changing legislation, and the release of associated guidance, to provide an overview to support stakeholders. Early consideration of how the changes might affect the building/s that you have fire safety responsibility for will help ensure that residents are kept safe and informed, and that changes to estates management can be pre-planned and arranged as effectively as possible. This page was last updated on 02/02/2023.

The Fire Safety Act

The (the Act) received Royal Assent on 29 April 2021 and commenced on 16 May 2022. 听The Act amends the Regulatory Reform (Fire Safety) Order 2005 (the Fire Safety Order).

Lancashire Fire & Rescue Service welcomes the commencement of the Fire Safety as important steps forward in strengthening the Fire Safety Order and improving fire safety. The Act clarifies that responsible persons (RPs) for multi-occupied residential buildings must manage and reduce the risk of fire for the structure and external walls of the building, including cladding, balconies and windows, and entrance doors to individual flats that open into common parts.

What does the Fire Safety Act do?

The Act clarifies that where a building contains 2 or more sets of domestic premises, the Fire Safety Order applies to:

  • the building鈥檚 structure and external walls (including windows, balconies, cladding, insulation and fixings) and any common parts
  • all doors between domestic premises and common parts such as flat entrance doors (or any other relevant door)

The Act provides greater clarity on where the Fire Safety Order applies in multi-occupied residential buildings. RPs must manage and reduce the risk of fire for:

  • 听the structure and external walls of the building, including anything attached to the exterior of those walls, such as cladding, balconies and windows; and
  • entrance doors to individual flats that open into common parts.

What is the Fire Risk Assessment Prioritisation Tool?

The Protection Policy Reform Unit has supported the Home Office Task and Finish Group in the production of a new Fire Risk Assessment Prioritisation Tool (FRAPT).

The FRAPT is an online tool designed to assist responsible persons to develop a strategy to prioritise their buildings to review their fire risk assessments, to ensure they take into account the clarifications outlined in the Act.

The Fire Risk Assessment Prioritisation Tool is available within The Fire Safety commencement prioritisation guidance,

This approach is also designed to ensure that competent professionals who have the required skills to assess external walls (such as fire engineers, fire risk assessors, surveyors, or architects) prioritise their resources to buildings identified as high priority.

The Fire Risk Assessment Prioritisation Tool does not constitute a fire risk assessment in itself, nor does it remove the need or requirement for both FRSs and RPs to act upon known or suspected risk in all premises.

Fire Safety (England) Regulations 2022 (Coming Into Force Jan 2023)

The Fire Safety (England) Regulations 2022 (the Regulations) came in to force on the 23rd January 2023. These are an important step towards implementing the recommendations of the Grenfell Tower Inquiry Phase 1 report. The Regulations were introduced under Article 24 of the Fire Safety Order.

The NFCC has released a 听[opens in a听new tab].

Why are these changes being introduced?

Following the devastating Grenfell Tower Fire in 2017, the Grenfell Tower Inquiry was established. To meet the Inquiry鈥檚 Phase 1 recommendations, the Fire Safety (England) Regulations 2022 (the Regulations) were introduced.

The Regulations apply to England only. The Regulations can be found at

What do the Fire Safety (England) regulations require responsible persons to do?

Most of the requirements set out in the Regulations are imposed on the responsible person (RP), which RPs need to plan and prepare for ahead of the Regulations coming into force.

The regulations require RPs in multi-occupied residential buildings to take specific actions, depending on the height of the building:

  • some provisions apply regardless of height
  • more are needed once a building reaches 11 metres, and
  • further requirements are introduced when a building reaches 18 metres (or 7 storeys) or more.

The Regulations set out requirements for responsible persons of all multi-occupied residential buildings, of two or more sets of domestic premises:

  • Fire Safety Instructions: they must provide relevant fire safety instructions to their residents on how to report a fire and what a resident must do once a fire has occurred.
  • Fire Door Information: provide residents with information relating to the importance of fire doors in fire safety.

The Regulations also set out requirements for RPs of multi-occupied residential buildings of over 11 metres in height:

  • Annual and quarterly checks fire door: They must undertake best endeavors to carry out annual checks of flat entrance doors. They must undertake quarterly checks of all fire doors in the common parts.

The Regulations for high-rise residential buildings (at least 18m or 7 storeys in height) also require responsible persons to:

  • Building Plans: provide their local FRS with up-to-date building floor plans by electronic means and to place a hard copy of these plans, alongside a single page building plan which identifies key firefighting equipment, in a secure information box on site.
  • External Wall Systems: provide to their local FRS information about the design and materials of a high-rise building鈥檚 external wall system and to inform the FRS of any material changes to these walls. Also, they will be required to provide information in relation to the level of risk that the design and materials of the external wall structure gives rise to and any mitigating steps taken.
  • Lifts and other Key Fire-Fighting Equipment: undertake monthly checks on the operation of lifts intended for use by firefighters, and evacuation lifts in their building and check the functionality of other key pieces of firefighting equipment.听 They will also be required to report any defective lifts or equipment to their local FRS as soon as possible after detection if the fault cannot be fixed within 24 hours, and to record the outcome of checks and make them available to residents.
  • Secure Information Boxes: install and maintain a secure information box in their building.听 This box must contain the name and contact details of the RP and hard copies of the building floor plans.
  • Wayfinding Signage: install signage visible in low light or smoky conditions that identifies flat and floor numbers in the stairwells of relevant buildings.

What do RPs need to do now?

RPs need to start planning now to be prepared for the changes. The PPRU is working with the Home Office to support the development of standard templates to assist both RPs and FRSs to ensure consistent and useful information is collected and received.

RPs are encouraged to:

  • Begin to use the Fire Risk Assessment Prioritisation Tool (the FRAPT), to start forming their fire risk assessment review prioritisation strategies. RPs should first consider the accompanying听. RPs should ensure their reviewed assessments take into account the requirements of the FSO (as amended).
  • Consider what necessary additional information they must share with FRSs and begin to submit. To find your relevant FRS Fire England have produced a search function via the site.
  • The preferred format for how RPs provide information to FRSs is detailed within the Home Office guidance located .

When will the changes take effect?

The FSA commenced on 16 May 2022. This means that RPs should now (if they have not already done so) consider when to review their fire risk assessments, to ensure these take account of any risk from the external wall. It is important that RPs are directed to, and consider the more detailed guidance from the Home Office about when and how to go about this.

A new Fire Risk Assessment Prioritisation Tool has been made available. The prioritisation tool is an online tool designed to support Responsible Persons to develop a prioritisation strategy for updating their fire risk assessments, following commencement. The prioritisation tool can be accessed within听The Fire Safety Act commencement guidance, available听.

The requirements to provide additional information to FRSs, The Fire Safety (England) Regulations 2022 came into force on 23 January 2023.

The UK Government published to support RPs to comply with the new Regulations.

Where can I find out more information?

You can find out more by visiting the

The Fire Safety Act can be found 听with factsheets and guidance The Fire Safety (England) Regulations can be found .

The Home Office has produced a series of 听which provide more detailed information on what the Regulations mean in England:

N.B. all the above links open on a new tab.

Assessment of External Wall Systems

Guidance on the assessment of External Wall Systems (EWS) was updated significantly in January 2022. The guidance applies to multi-occupied residential premises of all heights.

Until January 2022 the 鈥Consolidated Advice Note鈥 (CAN) applied. This guidance has been withdrawn but remains available for reference purposes at .

The most recent guidance, entitled 鈥PAS 9980:2022, Fire risk appraisal of external wall construction and cladding of existing blocks of flats 鈥 Code of practice鈥 is now available to download free of charge from .

PAS9980 provides guidance on when a Fire Risk Appraisal of External Walls (FRAEW) is likely to be needed, the competence required to undertake the assessment, the methodology to be applied and the resultant risk rating. If you are still unaware of the make-up and likely fire performance of your building鈥檚 EWS it is recommended that you instruct the services of a suitably qualified risk assessor, as future fire risk assessments are unlikely to be satisfactory without being able to evidence due consideration of the EWS make up and fire performance.

Proportionality applies, and the PAS 9980 includes a section describing the initial process to follow to determine if a full FRAEW is required. It is important to start with this assessment as traditionally constructed premises are unlikely to require a full FRAEW.

For further information see听.

Future Building Safety Bill

The Building Safety Bill is designed to give residents more power to hold builders and developers to account and toughen sanctions against those who threaten their safety.

A new Building Safety Regulator will oversee the new regime and be responsible for ensuring that any building safety risks in new and existing high rise residential buildings of 18m and above (or of seven storeys or more) are effectively managed and resolved.

Further updates are available at: .

Fire Safety Guidance in Purpose Built Flats

Fire safety guidance is currently being refined to accommodate the ongoing changes. Existing guidance, along with information on how to interpret and use it, is available in .

Simultaneous Evacuation Guidance

The National Fire Chief’s Council and our industry partners have published the fourth edition of the . The fourth edition replaces the third edition published in October 2020.

The SEG, which has been developed by fire safety professionals, seeks to actively discourage the ongoing and prolonged use of a waking watch. The latest edition makes a number of updates and improvements to discourage buildings from having onsite staffing where this may not be needed.

Guidance and Support for Leaseholders

A wide variety of fire safety advice and guidance is available on听.

Further Information

Contact our Business Fire Safety Team on听01772 866954 or send an email to听ProtectionSupport@lancsfirerescue.org.uk (opens new draft email)听for assistance.